stratumctl admin ovn

OVN substrate inspection (bootstrap-admin only)

Terminal window
stratumctl admin ovn [flags]

Check the OVN substrate against its invariants

Terminal window
stratumctl admin ovn doctor [flags]

Evaluate the network invariants that real outages were traced to, and report each as PASS / WARN / FAIL.

Read-only. Exits non-zero when any invariant is violated, so it composes:

Terminal window
stratumctl admin ovn doctor && echo network-healthy

WARN means an invariant could NOT be evaluated — not that it passed. That distinction is the point: on the outages behind every green light in the system was accurate about its own narrow claim and useless in aggregate, so a check that quietly passes when it did not run would reproduce the exact problem this command exists to solve.

Where an invariant came from a known bug, the report names the ticket.

Terminal window
stratumctl admin ovn doctor
stratumctl admin ovn doctor --output json

Trace a path through the OVN pipeline with the full substrate view

Terminal window
stratumctl admin ovn reachability [flags]

Aliases: reach

Evaluate a packet through the modeled OVN pipeline and print every hop with the substrate detail: OVN object names, ACL and routing-policy priorities, verbatim match expressions, NAT rows.

–from and –to take an address, optionally with the port that carries it:

Terminal window
192.0.2.11 resolve the port from the address
192.0.2.11@lsp-guest name the logical switch port directly
192.0.2.11@nic:nic-abc123 resolve the port from a NIC id
internet anything beyond the provider network

Unlike ‘stratumctl reachability’, this surface is install-scoped: it will answer about a platform port (IMDS, the DNS recursor, a subnet probe, any tenant’s load-balancer data plane) and across projects.

–trace corroborates the verdict against the dataplane by running ofproto/trace on the chassis hosting the ingress port, and reports whether the two agree. It does NOT override the verdict: a configuration model and a flow table disagreeing is information, not an error to resolve by preferring one source. The disagreement is the finding — “the configuration says this path is open, and the dataplane on chassis n-msst0002 drops it” is a sentence nothing else here can produce.

A trace is only meaningful on the chassis hosting the port, and there is no control-plane path to run a command on a chassis this process is not. When another node owns the port the analysis says which one, and refuses rather than reading the wrong flow table.

One pipeline model backs this and the tenant endpoint, so the two cannot disagree about a path — only about how much of it they show.

Terminal window
stratumctl admin ovn reachability --from 192.0.2.11@nic:nic-abc --to internet --port 443
stratumctl admin ovn reachability --from 192.0.2.11 --to 192.0.2.20 --protocol icmp --trace
Flag Type Default Description
--from string Source: <address>[@<lsp>|@nic:<id>] or ‘internet’ (required)
--port int 0 Destination port (required for tcp/udp)
--protocol string tcp Protocol: tcp, udp or icmp
--to string Destination: <address>[@<lsp>|@nic:<id>] or ‘internet’ (required)
--trace bool false Corroborate against the dataplane with ofproto/trace on the chassis hosting the port

Show the OVN substrate as a graph (text | mermaid | json)

Terminal window
stratumctl admin ovn topology [flags]

Read the OVN substrate’s logical topology from the controlplane and render it. –output controls the format:

Terminal window
text indented tree per VPC (default)
mermaid a graph TD block — paste into any Mermaid renderer
json raw graph (nodes + edges) for tooling

The implicit-SNAT-via-IGW row appears as a distinct node per IGW-enabled VPC — the substrate-level proof of the AWS-vs-Stratum delta documented in docs/operator/09-reference/aws-semantic-deltas.md.

Slice 2: –include-southbound queries the SB DB and adds chassis nodes + NIC→chassis edges. –include-ovs shells out to ‘ovs-vsctl show’ + ‘ovs-ofctl dump-flows br-int’ locally and attaches the result to the local chassis node. At v1 there’s one chassis; multi-chassis fan-out is.

Terminal window
stratumctl admin ovn topology
stratumctl admin ovn topology --vpc vpc-9k2m4x7q --include-southbound
stratumctl admin ovn topology --output json
Flag Type Default Description
--chassis string Restrict the SB DB pass to ports + chassis matching the given OVN chassis name
--include-ovs bool false Include local OVS bridge + br-int flow summary on the local chassis node
--include-southbound bool false Include OVN SB DB chassis correlation + NIC→chassis edges
--vpc string Restrict the graph to a single VPC’s subgraph