Shut down, reboot and cold start
Planned shutdowns are commands, not manual steps: Ceph’s flags and the instances’ shutdown are handled for you.
| You want to | Do |
|---|---|
| Reboot or power off one node | stratumctl nodes reboot <node-id>, or stratumctl nodes shutdown <node-id> |
| Keep its instances running meanwhile | stratumctl nodes drain <node-id> first |
| Power off the whole cluster | stratumctl admin cluster shutdown |
| Stop everything, power off yourself | stratumctl admin cluster shutdown --prepare-only |
| See where it is | stratumctl admin cluster shutdown status |
| Undo it before the nodes power off | stratumctl admin cluster shutdown cancel |
One node
Section titled “One node”stratumctl nodes reboot n-4k2x9m1q --reason "kernel update"stratumctl nodes shutdown n-4k2x9m1q --reason "replace a fan"See nodes reboot and
nodes shutdown. Console: Admin › Metal, the node, Shut down or Reboot. The cluster
holds the node in maintenance, so nothing is placed on it and no failover
starts. About 15 seconds later the node powers off or reboots itself. On the way
down it:
- sets Ceph’s
noouton its own OSDs only, so Ceph does not rebuild their data while the node is away; - asks every instance to shut down (ACPI), asks again every 20 seconds, and powers off the ones still running after 90 seconds;
- then stops the platform’s services.
On the way back the instances it stopped start again (unless their owner set
them to stopped), and noout is cleared once the node’s OSDs are up and in. If
an OSD is not back within 20 minutes the flag is cleared anyway.
A shut-down node stays off until you power it on. Its power button, or Wake-on-LAN to its management NIC where the firmware allows it.
A plain systemctl reboot on the node does the same drain, without the checks
below.
Refused when
Section titled “Refused when”| Code | Because |
|---|---|
QUORUM_AT_RISK |
The cluster would be left without a majority of control-plane nodes: a second node while one is down. --force overrides this one. |
UPGRADE_IN_PROGRESS, CLUSTER_SHUTDOWN_IN_PROGRESS |
Another operation is running. |
NODE_POWER_ACTION_IN_PROGRESS |
The node already has one. |
MIGRATION_IN_PROGRESS |
An instance is moving to or from it. |
NODE_NOT_REPORTING |
Its heartbeat lapsed: it is probably already off. |
Reboot one node at a time, and wait for stratumctl admin readiness to say
READY before the next. Two nodes down lose the Postgres, OpenBao, OVN and Ceph
monitor majorities. Readiness shows NodePowerAction while a node is down on
purpose, and a warning if a reboot has not come back after 20 minutes.
The whole cluster
Section titled “The whole cluster”stratumctl admin cluster shutdown --reason "power work in the rack"Confirm by typing the cluster id, or pass --confirm <cluster-id>
(admin cluster shutdown). The cluster:
- sets the Ceph flags
noout,norebalance,nobackfillandnorecover(flags already set are left alone, and not cleared afterwards); - stops every running instance, each with 60 seconds to shut down, and keeps its desired state;
- powers every node off, the one the command runs on last.
With --prepare-only it stops after step 2: power the nodes off in any order, or
cancel. status follows it, and readiness shows ClusterShutdown. Console:
Admin › Substrate › Cluster › Shutdown.
Cancel works until the nodes start powering off: it clears the flags and starts the instances. After that, power the nodes on.
Cold start
Section titled “Cold start”Power the nodes on, in any order. Nothing else is needed.
- Each node’s services start by themselves. OpenBao unseals from the node’s TPM, and Postgres, OpenBao and OVN re-form their clusters and elect leaders.
- The cluster waits for every node that was up at shutdown to report, and for every OSD to be up and in.
- It clears exactly the Ceph flags the shutdown set, and starts the instances that were running.
A node or OSD still missing after 30 minutes does not hold the flags: they are cleared anyway, and the message names what is missing.
A control plane that has just started judges no node dead until it has watched heartbeats itself for about 2 minutes, so a node that is merely still booting is not failed over. A cluster powered off without a shutdown comes back the same way.
To watch a node start: curl -s http://192.0.2.11:8443/startupz names the
phase it is in, and how long it has been there.